Nitrogen charging pump 1. Supercharged gas medium: Air, nitrogen (N2), helium (He), neon (Ne), argon (Ar), natural gas, gas, carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N2O), fire extinguishing agent, methane propane and other alkane gases, hospital breathing gas (N2+O2), sulfur hexafluoride gas (SF6), ethylene (C2H4), inert gas Body, etc. For special gases such as oxygen (O2), hydrogen (H2), refrigerant, corrosive gases, please specify in advance when ordering for special treatment.
基本资料
  • Nitrogen charging pump

    1. Supercharged gas medium:

    Air, nitrogen (N2), helium (He), neon (Ne), argon (Ar), natural gas, gas, carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N2O), fire extinguishing agent, methane propane and other alkane gases, hospital breathing gas (N2+O2), sulfur hexafluoride gas (SF6), ethylene (C2H4), inert gas Body, etc.

    For special gases such as oxygen (O2), hydrogen (H2), refrigerant, corrosive gases, please specify in advance when ordering for special treatment.

    Two, the working principle

    The driving air pressure is generally 3-8bar(0.3-0.8MPa), and the large piston is used to push the small piston to realize the output of high pressure gas at the end of the small piston. When the pressure is closer to the maximum output pressure of the pump, the pump frequency is slower and the flow is smaller.

    Three, booster pump function:

    Pressurize low pressure gas to achieve high pressure gas output.

    Can be customized according to customer requirements of complete sets of pressurization system, filling equipment, air tightness testing equipment, pressure test system, etc.

    Iv. Scope of Application:

    ① Applied to gas filling, filling, recovery, compression, pressurization and so on

    ② Welding robot gas high-pressure supply

    (3) Supporting gas pressurization equipment of gas proportioner

    ④ Suitable for high-pressure reactor gas pressurization

    ⑤ Insufficient gas pressure in the workshop for secondary pressurization

    Air tight test, high pressure test

    ⑦ Gas compression test and other occasions

    V. Technical parameters:

    Single stage double acting single head booster pump type selection technical parameter table

    GLD series gas booster pump is a single-acting single-stage booster pump mainly used for pressurizing gas with a certain initial pressure, and the flow rate is twice that of GLA series

    GLD series gas booster pump is a single-acting single-stage booster pump mainly used for pressurizing gas with a certain initial pressure, and the flow rate is twice that of GLA series

    Models including GLD04 / GLA06 / GLD25 GLD40 / GLD60 / GLD100 / GLD200 output pressure is proportional to the driving pressure, output pressure is adjustable.

    Model Pressure ratio Minimum inlet pressure

    (bar)

    Maximum output pressure

    (bar)

    Interface size

    Maximum normal flow

    (LN/min)

    Net weight

    (kg)

    Driving gas

    Gas inlet

    Gas outlet
    GLD04 4:1 3 80 NPT1/2 NPT1/2 NPT3/8 372 19.5
    GLD06 6:1 4 80 NPT1/2 NPT1/2 NPT3/8 260 19.5
    GLD10 10:1 5.5 80 NPT3/8 NPT3/8 NPT3/8 200 19.5
    GLD25 25:1 8 200 NPT1/4 NPT1/4 NPT1/4 154 19.5
    GLD40 40:1 15 320 NPT1/4 NPT1/4 NPT1/4 92 19.5
    GLD60 60:1 25 480 NPT1/4 NPT1/4 NPT1/4 115 19.5
    GLD100 100:1 35 800 NPT1/4 NPT1/4 M14*1.5 74 19.5
    GLD200 200:1 35 1300 ZG1/2 NPT1/4 M14*1.5 150 19.5
    The highest output pressure of GLD series booster pump = (booster ratio * driving pressure) + pressurized gas inlet pressure

    Example: GLD40 booster ratio 40:1, driving pressure 5bar, the existing pressure of pressurized gas 20bar, outlet pressure = (40*5) +20=220bar

    GLT series gas booster pump is double acting double stage booster pump, mainly used in the initial pressure of pressurized gas is very small, mainly pressurized compressed air or nitrogen production machine, but it needs to be pressurized to higher pressure occasions.

    The models include: GLT25, GLT40, GLT60, and GLT100

    Model Pressure ratio Minimum inlet pressure

    (bar)

    Maximum output pressure

    (bar)

    Interface size

    Maximum normal flow

    (LN/min)

    Net weight

    (kg)

    Driving gas

    Gas inlet

    Gas outlet
    GLT25 25:1 2 200 ZG1/2 NPT1/4 NPT1/4 136 21
    GLT40 40:1 2 320 ZG1/2 NPT1/4 NPT1/4 124 21
    GLT10/60 60:1 2 480 ZG1/2 NPT1/4 NPT1/4 84 21
    GLT25/60 60:1 2 480 ZG1/2 NPT1/4 NPT1/4 125 21
    GLT100 100:1 2 800 ZG1/2 NPT1/4 M14*1.5 63 21
    GLT series booster pump maximum output pressure = booster ratio * driving pressure
    Example: GLT40 booster ratio 40:1, driving pressure 5bar, the existing pressure of pressurized gas 4bar, outlet pressure =40*5=200bar