Focus on gas supercharging, liquid supercharging, gas - liquid supercharging technology application
GLTCN
服务热线 0531-85956889
Home » System scheme » Fatigue test stand » Hydraulic fatigue test bench – manual control mode
Hydraulic fatigue test bench – manual control mode
Hydraulic fatigue test bench - manual control mode Equipment introduction The fatigue test bench simulates the bearing parts in the actual working condition to carry out pressure alternating pulse test on the bearing parts to check whether it can complete the number of cycles specified in the standard, check its fatigue life and fatigue failure form. The equipment adopts manual control, the upper and lower limits of pressure, fatigue frequency and fatigue frequency are set by the instrument, the pressure transmitter collects the pressure of the system, the hose, various metal pipes, non-metallic pipes, joints and accessories and so on pressure test, check its fatigue life and fatigue failure form

Hydraulic fatigue test bench – manual control mode

Equipment introduction

The fatigue test bench simulates the bearing parts in the actual working condition to carry out pressure alternating pulse test on the bearing parts to check whether it can complete the number of cycles specified in the standard, check its fatigue life and fatigue failure form. The equipment adopts manual control, the upper and lower limits of pressure, fatigue frequency and fatigue frequency are set by the instrument, the pressure transmitter collects the pressure of the system, the hose, various metal pipes, non-metallic pipes, joints and accessories and so on pressure test, check its fatigue life and fatigue failure form.

Equipment composition

Pulse generator, pressure control gas, pressure sensor, pressure gauge, pressure regulating valve, high pressure valve, liquid tank, electrical control system, test case

Scope of application

Air conditioning pipe, condenser, etc

Technical parameter

No. Item Requirement Performance indicators
1. The pipeline of the subject is provided by the customer
2. Energy and pressure fatigue test
3. Test medium clean water or oil
4. Test pressure 0-6MPa
5. Pressure accuracy ±0.5MPa
6. The ambient temperature is room temperature
7. Supercharging pulse mode gas drive liquid pulse generator supercharging ratio 10:1
8. Pulse frequency 30 times /min
9. Test station 1 thread or sleeve connection
10. Control mode adopts digital display pressure controller to set pressure, counter to record cycle time, fatigue pressure, fatigue times can be set at will! Digital display table control
11. The number of single cycle 0-50,000 times (configurable)
12. The air source shall be 0.8MPa 1.0 cubic displacement provided by the customer